open
Download Folder Help  View Download Folder
Download Folder
Hide Download Folder

--

 

You are here: Home > Contractor > Underground Drainage Systems > Solid Wall Fittings

Product Selector
*

Solid Wall Fittings

Coupling

coupling combined
Code Size (mm) A (mm) B (mm) C (mm) Standards Desc.
UE300 82 103 50 48 - Ring seal/solvent socket (Fig. 4)
UE305 82 104 - - - Slip/double ring seal socket (Fig. 3)
UE400 110 109 61 48 BBA Standard logo British Standards Ring seal/solvent socket (Fig. 4)
UE402 110 311 82 - BBA Standard logo British Standards Ring seal socket/spigot, triple socket depth for use to accommodate ground movement/settlement (Fig. 5)
UE405 110 120 - - BBA Standard logo British Standards Slip/double ring seal socket (Fig. 3)
UE406 110 120 60 - BBA Standard logo British Standards Double ring seal socket (Fig. 2)
UE407 110 102 50 - - Double ring seal socket, polypropylene (Fig. 1)
UE600 160 190 107 77 BBA Standard logo British Standards Ring seal/solvent socket (Fig. 4)
UME15C 160 170 83 - BBA Standard logo British Standards Double ring seal socket (Fig. 2)
UME16C 160 170 - - BBA Standard logo British Standards Slip/double ring seal socket (Fig. 3)
*

Short Radius Bend

short radius bend combined
Code Size (mm) Angle (º) A (mm) B (mm) Desc. Standards
UB31 82 87.5º 117 120 Socket/spigot -
UB35 82 45º 75 73 Socket/spigot -
UB41 110 87.5º 175 182 Socket/spigots BBA Standard logo British Standards
UB411 110 87.5 158 158 Double socket BBA Standard logo British Standards
UB4155R 110 15 66 66 Double socket BBA Standard logo
UB415R 110 15 74 68 Socket/spigot BBA Standard logo
UB4300R 110 30 80 80 Double socket BBA Standard logo
UB430R 110 30 89 82 Socket/spigot BBA Standard logo
UB45 110 45 145 125 Socket/spigot (Fig. 2) BBA Standard logo British Standards
UB455R 110 45 75 75 Doube Socket (Fig. 1) BBA Standard logo
UB45R 110 45º 75 85 Socket/spigot BBA Standard logo
UB68 160 15º 150 110 Socket/spigot British Standards
UB69 160 30º 160 150 Socket/spigot British Standards
UFB61 160 87.5º 285 275 Socket/spigot BBA Standard logo British Standards
UFB65 160 45º 130 118 Socket/spigot BBA Standard logo British Standards
UMB11C 160 15º 95 95 Double socket BBA Standard logo
UMB13C 160 30º 105 105 Double socket BBA Standard logo
UMB14C 160 45º 115 115 Double socket BBA Standard logo
UMB19C 160 87.5º 200 200 Double socket BBA Standard logo
R-suffix denotes ribbed fitting
*

Long Radius Bend

long radius bend
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) Desc. Standards
UBL488 110 87.5 310 360 270 Socket/socket BBA Standard logo British Standards
UBL49 110 87.5º 310 920 270 With 900mm tail BBA Standard logo British Standards
Conforms to the requirements of BS EN 12056: 2000 for use at base of stack
*

Adjustable Bend

adjustable bend
Code Size (mm) Angle (º) A (mm) B (mm) Standards
UB37 82 11-87.5º 196 196 -
UB47 110 21-90 210 205 British Standards
UB67 160 15-90º 285 275 British Standards
Socket/spigot
*

Equal Branch

equal branch combined
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) Desc. Standards
UMY11C 160 45º 400 280 280 All socket (Fig. 2) BBA Standard logo
UMY13C 160 87.5º 400 200 - All socket BBA Standard logo
UY36 82 45º 231 155 155 Socket/spigot -
UY400 110 87.5º 300 150 - All socket British Standards
UY400R 110 87.5º 245 135 - All socket BBA Standard logo
UY401 110 87.5 300 150 - Socket/spigot -
UY401R 110 87.5º 250 135 - Socket/spigot BBA Standard logo
UY46 110 45 320 205 205 Socket/spigot (Fig. 1) BBA Standard logo British Standards
UY466 110 45º 325 215 200 All socket British Standards
UY466R 110 45º 280 200 200 All socket BBA Standard logo
UY46R 110 45º 300 200 200 Socket/spigot BBA Standard logo
UY601 160 87.5º 400 200 - Socket/spigot -
UY63 160 45º 400 280 280 Socket/spigot BBA Standard logo British Standards
R-suffix denotes ribbed fitting
*

Unequal branch

unequal branch combined
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) Desc. Standards
UMY10C 160x110 45º 316 232 236 All socket (Fig. 2) BBA Standard logo
UMY12C 160x110 87.5º 340 180 252 All socket BBA Standard logo
UY64 160x110 87.5º 340 180 126 Socket/spigot -
UY66 160x110 45º 357 245 254 Socket/spigot (Fig. 1) BBA Standard logo British Standards
*

Access Pipe

access pipe
Code Size (mm) A (mm) B (mm) C (mm) D (mm) Standards
UF42 110 332 160 82 170 BBA Standard logo British Standards
Socket/spigot, 150mm access
*

Access Branch

access branch
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) Desc. Standards
UY471 110x110 45º 330 210 210 Left hand BBA Standard logo British Standards
UY472 110x110 45º 330 210 210 Right hand (illustrated opposite) BBA Standard logo British Standards
Socket/spigot, 150mm access
*

Access Double Branch

access double branch
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) Standards
UY404 110 45º 344 205 205 BBA Standard logo British Standards
Socket/spigot, 150mm access
*

Access Bend

access bend
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) Standards
UB42 110 87.5 172 174 80 British Standards
With rear access, ring seal socket/spigot. fitted with a twist and lock access cap which can be secured with a No. 8 screw.
*

Rodding Point Terminal

rodding point terminal
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) Desc. Standards
URP1 110 45 160 68 70 A15 loading to BS EN 124:1994. Black cover with four screw fixings and seal BBA Standard logo British Standards
URP2C 160 45º 190 92 89 35kN test load suitable for driveway applications when supported with concrete surround. Aluminium cover with two screw fixings (illustrated) -
35kN test load suitable for driveway applications when supported with concrete surround. Aluminium cover with two screw fixings
*

Access Cap

access cap
Code Size (mm) A (mm) B (mm)
UE30 82 110 35
Solvent socket
*

Access Cap & Pressure Plug

access cap and pressure plug
Code Size (mm) A (mm) B (mm) Standards
UE42 110 130 30 BBA Standard logo
UE62 160 195 40 -
Solvent socket
*

Pressure Plug

pressure plug
Code Size (mm) A (mm) B (mm)
UE43 110 110 30
UE64 160 160 30
Push fits into plain end of pipe
*

Level Invert Reducer

level invert reducer
Code Size (mm) A (mm) B (mm) C (mm) Standards
URM304 110x82 135 67 54 BBA Standard logo British Standards
URM604 160x110 219 90 82 BBA Standard logo British Standards
Socket/spigot
*

Reducer

reducers combined
Code Size (mm) A (mm) B (mm) C (mm) Desc. Standards
SE41 110x50 103 80 19 Spigot to standard waste boss upstand (Fig. 3) British Standards
SRM30 82x50 70 48 19 Solvent socket to standard waste boss upstand (Fig. 2) -
SRM325 82x68 35 20 12 Solvent socket to 68mm downpipe (Fig. 1) -
SRM402 110x50 48 25 19 Solvent socket to standard waste boss upstand (Fig. 2) -
URM425 110x68 40 25 21 Solvent socket to 68mm downpipe (Fig. 1) -
*

Adaptor

adaptors combined
Code Size (mm) A (mm) B (mm) C (mm) Desc. Standards
UA41 110 102 133 82 PVCu pipe socket to salt glazed/pitched fibre pipe socket (Fig. 1) BBA Standard logo British Standards
UA42 110 31 104 - Rainwater to 110mm drain (Fig. 4) -
UA43 110 58 25 34 Universal waste to 110mm drain (Fig. 5) -
UA47 110 125 159 58 Salt glazed/cast iron pipe spigot to PVCu pipe spigot (Fig. 2) -
UCA40 110 120 110 130 Socket/socket to suit thin wall clayware pipe (Fig. 3) -
UCA41 110 120 110 138 Socket/socket to suit thick wall clayware pipe (Fig. 3) -
*

Bottle Gully

bottle gully
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) D (mm) Desc. Standards
UG50 110 87.5 237 277 152 95 A15 load class to BS EN 124: 1994. Ring seal socket outlet, three 110mm solvent weld inlets with 50mm boss upstands and rodding access British Standards
UG50D 110 87.5º 237 277 152 95 With 110mm rear inlet open British Standards
UG50SA 110 87.5º 237 277 152 95 With sealed lid British Standards
*

Bottle Gully Raising Piece

bottle gully raising piece
Code Size (mm) A (mm) B (mm)
UG52 110 160 352
150mm Quantum pipe for use with bottle gully UG50 to adjust invert level of trap outlet
*

Compact Gully

compact gully
Code Size (mm) Angle (º) A (mm) B (mm) C (mm)
UG40 110 45 280 385 232
Ring seal socket outlet, accepts 68mm downpipe inside larger boss with three 50mm boss upstands and rodding access
*

Gully Trap

gully trap
Code Size (mm) Angle (º) A (mm) B (mm) C (mm) Desc. Standards
UG42 110 87.5 240 270 215 Ring seal socket inlet and oulet British Standards
UG44 110 45 170 294 28 Solvent socket inlet, spigot outlet British Standards
*

Gully Hopper

gully hopper
Code Size (mm) A (mm) B (mm) C (mm)
UG47 110 232 142 50
UG48 110 160 142 50
Solvent socket, accepts 68mm downpipe inside larger boss with two 50mm boss upstands. Grating meets requirements of BS 4660: 2000 load Class K3
*

Gully Grating

gully grating
Code Size (mm) A (mm) B (mm) C (mm)
UG45 110 162 55 28
Solvent socket. Grating meets requirements of BS 4660: 2000 load Class K3
*

Gully Inlet Raising Piece

gully inlet raising
Code Size (mm) A (mm) B (mm) C (mm)
UW401 110 181 125