Have a question on our Waste range? Need to know what fall the pipe should be at or whether ABS can be used outside? Our Technical team have come up with a list of frequently asked questions to help.

If we haven't answered your question then please call us on 01622 852695 where one of our knowledgeable staff will be able to assist you.

Frequently Asked Waste Questions

How do I connect Polypropylene waste pipes together?

Push fit ring seal or compression fittings. Polypropylene can not be solvent welded

What temperature of water can I continually discharge through soil and waste pipes?

Although they are tested at 93.0 to 95.0ºc {British Standard test} this is an intermitted hot and cold cycle test. For a continuous discharge, water should be no hotter than 70 to 75ºC. Higher temperature water will not cause problems as long as it is restricted to 2 minutes discharge.

Can I connect Marley’s 110mm &160mm soil and waste pipes to a competitor product?

Yes. As long as the soil pipes are manufactured to [BS4514] BSEN1329 PVC or ABS waste pipes can be interchanged as long as they are manufactured to [BS5255]- BSEN1329-BSEN1455 Polypropylene pipes can be interchanged as long as they are manufactured to [BS5254]-BSEN1451

What fall can I fit waste pipes?

18mm per 1 metre minimum gradient

What diameter pipe do I use to connect the following: Sink, Bath, Basin or Shower Connection?

Sink: 40mm 1½ Bath: 40mm 1½ Basin: 32mm 1¼ Shower Connection: 40mm 1½ These are nominal sizes used for reference only

What is the maximum length of waste pipe can I fit to: Sink, Bath, Basin or Shower?

Sink: No limit Bath: No limit Basin: 1.7metre for 32mm- 3metre for 40mm over 3 increase too 50mm 2 Shower: No limit All waste pipes should be fitted at gradient of 18mm per 1 metre minimum

Can I fit ABS waste pipes externally?

Yes as long as they are painted

Can I fit Polypropylene waste pipes externally?

Yes as long as they are painted

Can I fit MUPVC waste pipe externally?

Yes no painting required

How do I connect waste pipes to a soil stack?

Use a separate multi-fit boss connector, boss branch or strap on boss for each size waste pipe.

Should l allow expansion on waste pipes?

Yes, A expansion coupling should be fitted at every 1.8 metre centres